APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11252 Issued:2010-05-06
Revised:2011-10-18
Style 11252 Single conductor with extruded insulation.

Rating105 deg C Dry, 90 deg C wet, 600 Vac, Horizontal flame. Optional: Oil Res 75C.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationExtruded PVC, 15 mils min average, 13 mils minimum at any point. See Facing Page for Compound.
CoveringExtruded Nylon covering, 4 mils minimum thickness, maximum thickness in accordance with the Standard.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances.