APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11257 Issued:2010-06-04
Revised:2011-08-12
Style 11257 Single conductor cable using extruded non-integral jacket

Rating125 deg C, 30 Vac Horizontal flame.
Conductor50 AWG - 10 AWG solid or stranded.
InsulationExtruded foamed FEP with extruded solid FEP outer skin, 3.0 mils total minimum average thickness, 2.7 mils total minimum thickness at any point.
ShieldOptional.
JacketExtruded PFA, 1.0 mil minimum average thickness, 0.8 mil minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2025