APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11260 Issued:2010-06-04
Revised:2011-10-20
Style 11260 Single conductor cable using non-integral jacket.

Rating125 deg C, 30 Vac Horizontal flame.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationFoamed FEP with solid outer PFA skin, 3.0 mils total minimum average thickness, 2.7 mils total minimum thickness at any point.
ShieldOptional.
JacketPFA, 1.0 mil minimum average thickness, 0.8 mil minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2025