APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11261 Issued:2010-06-04
Revised:2011-10-19
Style 11261 Single-conductor cable using non-integral jacket.

Rating125 deg C, 30 Vac Horizontal flame.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationExtruded Foamed FEP with solid PFA outer skin, 3.0 mils total minimum average thickness, 2.7 mils total minimum thickness at any point.
ShieldOptional.
JacketExtruded ETFE, 1.0 mil minimum average thickness, 0.8 mil minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.