APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11264 Issued:2010-06-04
Revised:2012-04-19
Style 11264 Single conductor with extrued insulation and jacket

Rating125 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationFoamed PFA with solid PFA outer skin, 3.0 mils total minimum average thickness, 2.7 mils total minimum thickness at any point.
ShieldOptional.
JacketETFE, 1.0 mil minimum average thickness, 0.8 mil minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.