APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11281 Issued:2010-08-20
Revised:2011-08-12
Style 11281 Single conductor cable using extruded non-integral jacket

Rating150 deg C, 150 Vac, Horizontal flame.
ConductorSolid or stranded or Litz cable magnet wire, R/C (OBMW2) magnet wire rated min 150 deg C. AWG size to be determined by the Resistance Test per UL 1581.
InsulationExtruded PTFE, 6.6 mils minimum average thickness, 6 mils minimum thickness at any point.
ShieldOptional.
CoveringOptional, extruded FEP, 4.5 mils minimum average thickness or heavier; or extruded PFA, PTFE 5.5 mils minimum average thickness or heavier.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances, where not subjected to movement or mechanical damage.

UL and the UL Logo are trademarks of UL LLC © 2024