APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1135 Issued:1959-05-01
Revised:2011-07-28
Style 1135 Single conductor with extruded insulation

Rating90 deg C, 300 Vac, Horizontal flame.
ConductorMinimum 1.75 mils diameter resistance wire wound for a mininum of 25 turns per inch on a Rayon, Cotton, Polyester, Fiberglass or Nylon yarn core
InsulationExtruded PVC, 45 mils min average, 40 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor refrigerator mullion heating where not subjected to repeated flexing in use.