Rating | 80 deg C,30 Vac, Cable flame, VW-1 flame. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM Procedure having a minimum rating of 80 deg C and 30 V. |
|
Shield | Optional. |
|
Covering | Optional for one layer jacket. None for two layers jacket. |
|
Jacket | PVC. One layer or two layers jacket, thickness in accordance with the table below. Two layers jacket are extruded simultaneously and not separable in the same base compound, but should be differed with colour. The thickness of individual layer is not specified.
One layer jacket Thickness (mils) or two layers total thickness (mils) |
| Dia. of assembly under jacket in inches | minimum average thickness | minimum thickness at any point |
| 0 - 0.400 | 24 mils | 20 mils |
| 0.401 - 0.700 | 30 mils | 24 mils |
| 0.701 - 1.500 | 45 mils | 36 mils |
| 1.501 - 2.500 | 60 mils | 48 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|