Rating | 105 deg C, 300 Vac, Horizontal flame. |
|
Conductor | No. 28 AWG or larger solid or stranded resistance wire alloy, or minimum 1.3 mils diameter resistance wire wound for a minimum of 10 turns per inch on a Rayon, Cotton, Polyester, Fiberglass, or Nylon yarn core. Core may be coated with Silicon Rubber. |
|
Insulation | PVC, 30 mils min average, 27 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|