APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1145 Issued:1959-05-01
Revised:2011-07-28
Style 1145 Single Conductor with extruded insulation

Rating75 deg C, 125 Vac, Horizontal flame.
ConductorA copper alloy heater wire shall be flattened to a width of 13 to 19 mils and wrapped spirally for a minimum of 36 turns per inch on a glass yarn core. The core and conductor are then insulated with two extruded walls of nylon (avg. thickness of first wall, 6 mils; avg. thickness of second wall, 5 mils). Over the nylon a copper alloy signal wire, flattened to a width of 13 to 19 mils, shall be wrapped spirally for a minimum of 20 turns per inch.
InsulationPVC, 20 mils min average, 18 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn Electrically Heated Blankets where exposed to temperatures not exceeding 75 deg C.