APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11464 Issued:2012-05-30
Revised:New
Style 11464 Single conductor with non-integral jacket.

Rating80 deg C, 150 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's Procedure.
JacketExtruded mPPE-PE, 24 mils minimum average thickness, 19 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.