Rating | 80 deg C,30 Vac, Horizontal flame. |
|
Conductor | 44 AWG min., solid or stranded. |
|
Insulation | Extruded TPES, 4 mils minimum average thickness, 3 mils minimum thickness at any point. |
|
Inner Covering | Optional. Extruded PVC or extruded PFA or extruded Nylon or extruded Polyester or extruded PVDF or extruded FEP or extruded PTFE or extruded ECTFE or extruded ETFE or extruded PE or extruded XLPE or extruded XLFRPE or extruded FRPE or non-extruded Non-metallic Braid or non-extruded heat sealed PTFE tape or non-extruded heat sealed PFA tape or non-extruded heat sealed FEP tape or non-extruded Polyester film or non-extruded Polyester-Polyethylene film. Thicknesses not specified. |
|
Inner Shield | Optional. |
|
Middle Covering | Optional. Extruded PVC or extruded PFA or extruded Nylon or extruded Polyester or extruded PVDF or extruded FEP or extruded PTFE or extruded ECTFE or extruded ETFE or extruded PE or extruded XLPE or extruded XLFRPE or extruded FRPE or non-extruded Non-metallic Braid or non-extruded heat sealed PTFE tape or non-extruded heat sealed PFA tape or non-extruded heat sealed FEP tape or non-extruded Polyester film or non-extruded Polyester-Polyethylene film. Thicknesses not specified. |
|
Outer Shield | Required, provided under the outer covering. |
|
Outer Covering | Required. Extruded XLPE or extruded XLPVC or extruded TPU or extruded PVC or extruded PFA or extruded PP or extruded Nylon or extruded Polyester or extruded PVDF or extruded FEP or extruded PTFE or extruded ECTFE or extruded ETFE or extruded PE or extruded XLFRPE or extruded FRPE or non-extruded lacquered braids or non-extruded heat sealed PTFE tape or non-extruded heat sealed PVC tape or non-extruded heat sealed PFA tape or non-extruded heat sealed FEP tape or anon-extruded Polyester film or a non-extruded Polyester-Polyethylene film. Thickness not specified. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Class 2 Circuits or for further processing. |
|