APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11483 Issued:2012-07-16
Revised:New
Style 11483 Single conductor with extruded insulation

Rating80 deg C,30 Vac, Horizontal flame.
Conductor44 AWG min., solid or stranded.
InsulationExtruded TPES, 4 mils minimum average thickness, 3 mils minimum thickness at any point.
Inner CoveringOptional. Extruded PVC or extruded PFA or extruded Nylon or extruded Polyester or extruded PVDF or extruded FEP or extruded PTFE or extruded ECTFE or extruded ETFE or extruded PE or extruded XLPE or extruded XLFRPE or extruded FRPE or non-extruded Non-metallic Braid or non-extruded heat sealed PTFE tape or non-extruded heat sealed PFA tape or non-extruded heat sealed FEP tape or non-extruded Polyester film or non-extruded Polyester-Polyethylene film. Thicknesses not specified.
Inner ShieldOptional.
Middle CoveringOptional. Extruded PVC or extruded PFA or extruded Nylon or extruded Polyester or extruded PVDF or extruded FEP or extruded PTFE or extruded ECTFE or extruded ETFE or extruded PE or extruded XLPE or extruded XLFRPE or extruded FRPE or non-extruded Non-metallic Braid or non-extruded heat sealed PTFE tape or non-extruded heat sealed PFA tape or non-extruded heat sealed FEP tape or non-extruded Polyester film or non-extruded Polyester-Polyethylene film. Thicknesses not specified.
Outer ShieldRequired, provided under the outer covering.
Outer CoveringRequired. Extruded XLPE or extruded XLPVC or extruded TPU or extruded PVC or extruded PFA or extruded PP or extruded Nylon or extruded Polyester or extruded PVDF or extruded FEP or extruded PTFE or extruded ECTFE or extruded ETFE or extruded PE or extruded XLFRPE or extruded FRPE or non-extruded lacquered braids or non-extruded heat sealed PTFE tape or non-extruded heat sealed PVC tape or non-extruded heat sealed PFA tape or non-extruded heat sealed FEP tape or anon-extruded Polyester film or a non-extruded Polyester-Polyethylene film. Thickness not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits or for further processing.

UL and the UL Logo are trademarks of UL LLC © 2024