Subj.758 Section 1 Page 1151 Issued:1959-05-01
Revised:2012-04-22
Style 1151 Single conductor with extruded insulation

Rating80 deg C, 125 Vac, Horizontal flame.
ConductorA nichrome conductor, minimum diameter 0.0025 inches, wound for a minimum of 20 turns per inch on a Fiberglass, Polyester, or Nylon core.
InsulationPVC, 30 mils minimum average thickness, 27 mils thickness minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.