Rating | 80 deg C, 1000 Vac, Cable flame. |
|
Conductor | 5 AWG - 1000 kcmil, solid or stranded. |
|
Insulation | Extruded TPES |
| AWG Conductor Size | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 5-3 | 35 | 28 |
| 3-1/0 | 44 | 35 |
| 2/0-3/0 | 47 | 38 |
| 250-300 | 51 | 42 |
| 301-400 | 59 | 49 |
| 401-500 kcmil | 79 | 67 |
| 600 kcmil | 99 | 85 |
| 1000 kcmil | 119 | 103 |
|
Assembly | Conductor, optional fleece wrap, TPES insulation, optional fleece wrap, TPU Inner covering (35 mils or heavier may be extruded over the conductor assembly), optional fleece wrap, optional tinned copper braid, optional fleece wrap, covered by TPU Outer Jacket |
|
Inner Jacket / Covering | Extruded TPU |
| AWG Conductor Size | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 5-3 | 35 | 28 |
| 3-1/0 | 40 | 32 |
| 2/0-3/0 | 44 | 35 |
| 250-300 | 48 | 39 |
| 301-400 | 55 | 46 |
| 401-500 kcmil | 59 | 49 |
| 600 kcmil | 63 | 53 |
| 1000 kcmil | 79 | 67 |
|
Shield | Optional (Tinned copper wire braid) |
|
Outer Jacket | Extruded TPU |
| AWG Conductor Size | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 5-3 | 47 | 39 |
| 3-1/0 | 55 | 46 |
| 2/0-3/0 | 59 | 49 |
| 250-300 | 63 | 53 |
| 301-400 | 71 | 60 |
| 401-500 kcmil | 79 | 67 |
| 600 kcmil | 87 | 75 |
| 1000 kcmil | 95 | 81 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|