Style 11526 Single Conductor with Extruded Insulation and Non-Integral Jacket

Rating80 deg C, 1000 Vac, Cable flame.
Conductor5 AWG - 1000 kcmil, solid or stranded.
InsulationExtruded TPES
AWG Conductor SizeMinimum average thickness (mils)Minimum thickness at any point (mils)
5-33528
3-1/04435
2/0-3/04738
250-3005142
301-4005949
401-500 kcmil7967
600 kcmil9985
1000 kcmil119103
AssemblyConductor, optional fleece wrap, TPES insulation, optional fleece wrap, TPU Inner covering (35 mils or heavier may be extruded over the conductor assembly), optional fleece wrap, optional tinned copper braid, optional fleece wrap, covered by TPU Outer Jacket
Inner Jacket / CoveringExtruded TPU
AWG Conductor SizeMinimum average thickness (mils)Minimum thickness at any point (mils)
5-33528
3-1/04032
2/0-3/04435
250-3004839
301-4005546
401-500 kcmil5949
600 kcmil6353
1000 kcmil7967
ShieldOptional (Tinned copper wire braid)
Outer JacketExtruded TPU
AWG Conductor SizeMinimum average thickness (mils)Minimum thickness at any point (mils)
5-34739
3-1/05546
2/0-3/05949
250-3006353
301-4007160
401-500 kcmil7967
600 kcmil8775
1000 kcmil9581
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.