Style 11534 Single conductor with extruded insulation and other-than-extruded covering

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor44 AWG - 30 AWG, solid or stranded.
InsulationExtruded PFA which consists of two concentric tubes with integral bridges to maintain air gap between tubes, overall thickness - 3 mils min average and 2 mils min at any point, inner tube thickness - 0.04 mils min at any point, outer tube thickness - 0.16 mils min at any point, and inter bridge thickness - 0.04 mils min at any point.
ShieldOptional.
CoveringPolyester tape with polyester adhesive, total layers thickness 0.2 mils min at any point, spirally wrapped and heat sealed.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.