APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11543 Issued:2014-01-30
Revised:2014-01-31
Style 11543 Single Conductor with Extruded Insulation and Jacket

Rating105 deg C, 1000 Vac, 1200 Vdc, Horizontal flame.
Conductor20 AWG - 500 kcmil, solid or stranded.
Semi-con LayerOptional - Semi-conductive Polymeric Layer, Extruded PVC
Conductor sizeMinimum thickness at any point
20 AWG5 mils
18-16 AWG6 mils
14-12 AWG8 mils
10-8 AWG10 mils
6-2 AWG13 mils
1-4/0 AWG17 mils
250-500 kcmil20 mils
InsulationExtruded PVC
Conductor sizeMinimum average thicknessMinimum thickness at any point
20 - 11 AWG15 mils13 mils
10 - 9 AWG20 ave18 min
8 - 5 AWG30 avg27 min
4 - 2 AWG40 avg36 min
1-4/0 AWG50 avg45 min
213-500 kcmil60 avg54 min
CoveringExtruded Polyamide (Nylon)
Conductor sizeMinimum thickness at any point
20-9 AWG4 mils
8-5 AWG5 mils
4-2 AWG6 mils
1-4/0 AWG7 mils
213 - 500 kcmil8 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor further processing.

UL and the UL Logo are trademarks of UL LLC © 2024