APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11573 Issued:2014-10-07
Revised:New
Style 11573 Single conductor with extruded insulation and non-extruded covering as the outermost layer.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG - 30 AWG, solid or stranded.
InsulationExtruded PFA which consists of two concentric tubes with integral bridges to maintain air gap between tubes, overall thickness - 1.5 mils min average and 1.3 mils min at any point, inner tube thickness - 0.32 mils min at any point, outer tube thickness - 0.58 mils min at any point, and inter bridge thickness - 0.81 mils min at any point.
ShieldOptional.
CoveringPolyester tape with polyester adhesive, total layers thickness 0.2 mils min at any point, spirally wrapped and heat sealed.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024