APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11596 Issued:2015-01-07
Revised:New
Style 11596 Single conductor with extruded insulation and other-than-extruded covering

Rating90 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG - 30 AWG, solid or stranded.
InsulationExtruded PFA, 1.5 mil minimum average thickness, 1.3 mil minimum thickness at any point.
Inner CoveringPET tape with polyester adhesive, 0.3 mil minimum combined thickness of all layers of tape and adhesive, spirally wrapped and heat sealed.
Outer CoveringAL/PET or CU/PET tape with polyester adhesives, 0.6 mil minimum combined thickness of all layers of tape and adhesives, spirally wrapped and heat sealed. AL or CU layer in AL/PET or CU/PET tape shall be exposed as outermost layer.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024