APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11608 Issued:2015-05-15
Revised:2019-11-07
Style 11608 Single Conductor Cable with Extruded Non-integral Jacket.

Rating75 deg C, 600 Vac Cable flame.
Conductor30 AWG min., solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
ShieldOptional.
CoveringOptional. A barrier layer if employed, may be a fibrous wrap, serving or braid; Paper; Nylon: oriented Polyethylene terephthalate; or a thermoplastic tape wrap.
JacketExtruded PVC
dia in inches 0.700 or less30 mils min average24 mils minimum at any point
1.000 dia or less45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501-4.00 dia110 avg88 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external wiring.