APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11618 Issued:2015-07-30
Revised:New
Style 11618 Single conductor with extruded insulation and non-extruded covering as the outermost layer.

Rating90 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationNon-separable, extruded foamed FEP with solid FEP skin layer, 3.0 mils total minimum average thickness, 2.7 mils total minimum thickness at any point.
ShieldOptional.
CoveringPET tape with polyester adhesive, total layers thickness 0.2 mils minimum at any point, spirally wrapped.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025