| Rating | 80 deg C, 600 Vac, Cable flame. |
|
| Conductor | 32 AWG - 26 AWG, solid or stranded. |
|
| Insulation | Inner Insulation - Extruded PE, 11 mils minimum average thickness, 9 mils minimum thickness at any point. Semi Conductive Insulation - Optional, PVC. Middle Insulation - Extruded PE, 9 mils minimum average thickness, 7 mils minimum thickness at any point. Outer Insulation - 9 mils minimum average thickness, 7 mils minimum thickness at any point. |
|
| Assembly | From inner to outer: Inner Conductor, Inner Insulation, optional Semi Conductive Insulation, Inner Shield, Middle Insulation, Outer Conductor, Outer Insulation, Outer Shield, optional Aramid braid, optional tape, PVC covering and overall Jacket. |
|
| Shields | Metal shields and/or braids. |
|
| Covering | Extruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. |
|
| Jacket | Extruded FEP, 10 mils minimum average thickness, 8 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | External Wiring. |
|