APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11629 Issued:2015-10-15
Revised:2015-10-19
Style 11629 Single conductor cable with extruded non-integral jacket.

Rating80 deg C, 600 Vac, Cable flame.
Conductor32 AWG - 26 AWG, solid or stranded.
InsulationInner Insulation - Extruded PE, 11 mils minimum average thickness, 9 mils minimum thickness at any point. Semi Conductive Insulation - Optional, PVC. Middle Insulation - Extruded PE, 9 mils minimum average thickness, 7 mils minimum thickness at any point. Outer Insulation - 9 mils minimum average thickness, 7 mils minimum thickness at any point.
AssemblyFrom inner to outer: Inner Conductor, Inner Insulation, optional Semi Conductive Insulation, Inner Shield, Middle Insulation, Outer Conductor, Outer Insulation, Outer Shield, optional Aramid braid, optional tape, PVC covering and overall Jacket.
ShieldsMetal shields and/or braids.
CoveringExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
JacketExtruded FEP, 10 mils minimum average thickness, 8 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024