APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1163 Issued:1959-05-01
Revised:2012-03-30
Style 1163 Single conductor with extruded insulation.

Rating105 deg C, 300 Vac, Horizontal flame. Optional - Oil Resistant 60 deg C or 80 deg C.
Conductor20 AWG - 16 AWG. 20 AWG shall be solid or stranded. 18 AWG - 16 AWG shall be stranded. All stranded conductors shall consist of 30 AWG or smaller strands.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Lighting Circuits in Refrigerating Equipment where exposed to temperatures not exceeding 105 deg C; or Internal Wiring of Lighting Circuits in Refrigerating Equipment where exposed to temperatures not exceeding 105 deg C, or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable).

UL and the UL Logo are trademarks of UL LLC © 2024