APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1165 Issued:1959-05-01
Revised:2011-09-02
Style 1165 Single-conductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, 300 Vac, Horizontal flame. Optional - 60 deg C Oil.
Conductor26 AWG - 16 AWG, solid or stranded.
InsulationExtruded PE, 15 mils minimum average thickness, 13 mils minimum thicknes at any point.
JacketExtruded PVC, 6 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring in appliances.

UL and the UL Logo are trademarks of UL LLC © 2024