APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11680 Issued:2017-02-08
Revised:New
Style 11680 Single conductor with extruded insulation and extruded non-integral jacket

Rating80 deg C,600 Vac, Horizontal flame and VW-1 flame.
Conductor50 AWG - 1 AWG, solid or stranded.
InsulationExtruded PE insulation with minimum average thickness 10 mils, minimum thickness at any point 9 mils.
AssemblyOne insulated single conductor employing PE insulation, inner metal braid over the insulation, optional binder, optional inner PE jacket, 2 metal braids and overall jacket.
Inner ShieldRequired. A metal braid shall be provided over the insulation.
Inner JacketOptional. An extruded PE jacket may be provided over the inner shield and under the middle shield. Thickness not specified.
Middle ShieldRequired. A metal braid shall be provided over the inner jacket and under the outer shield.
Outer ShieldRequired. A metal braid shall be provided under the overall jacket.
JacketExtruded TPU with 28 mils minimum average thickness, 22 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial - Internal Wiring with required VW-1 flame rating.