APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1172 Issued:1959-05-01
Revised:2011-07-28
Style 1172 Single conductor with extruded insulation

Rating105 deg C, 300 Vac, Horizontal flame.
ConductorMinimum 0.0015 inch diameter resistance wire wound for a minimum of 10 turns per inch on a Polyester yarn or Fiberglass yarn core. A glass braid spacer shall be employed between the conductor and insulation.
InsulationPVC, 30 mils min average, 27 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerators where exosed to temperatures not exceeding 105 deg C and where not subjected to flexing or motion.