Style 11734 Single conductor with extruded insulation

Rating80 deg C, 1000 Vac, Horizontal flame.
Conductor32 AWG - 750 kcmil, solid or stranded.
InsulationExtruded PE or FRPE.
Conductor SizeMinimum average thicknessMinimum thickness at any point
32-5 AWG30 mils27 mils
4-2 AWG40 mils35 mils
1-4/0 AWG45 mils42 mils
250 -500 kcmil60 mils54 mils
500 -750 kcmil80 mils72 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.