APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11736 Issued:2017-12-28
Revised:2017-12-27
Style 11736 Single conductor cable using non-integral jacket.

Rating200 deg C,90 Vac, Horizontal flame.
Conductor36 AWG - 16 AWG, solid or stranded.
InsulationExtruded non-separable two layers PFA. Each layer consists of an inner tube and an outer tube joined together by webs. Inner layer - Overall 2.0 mils minimum average thickness and 1.8 mils minimum at any point, including air gap between the tubes. Individual tube and web 1.0 mil minimum at any point. Outer layer - Overall 5 mils minimum average thickness and 4 mils minimum at any point, including air gap between the tubes. Individual tube and web 1.1 mils minimum at any point.
ShieldOptional
JacketExtruded FEP, 2.0 mils minimum average thickness, 1.6 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024