APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11749 Issued:2018-04-16
Revised:New
Style 11749 Single conductor cable with extruded non-integral jacket

Rating80 deg C, 600 Vac, Horizontal Flame.
Conductor32 AWG - 26 AWG, Solid or Stranded Round.
InsulationInner Insulation - Extruded PE, 11 mils minimum average thickness, 9 mils minimum thickness at any point. Semi Conductive Insulation - Optional, PVC. Middle Insulation - Extruded PE, 9 mils minimum average thickness, 7 mils minimum thickness at any point. Outer Insulation - 9 mils minimum average thickness, 7 mils minimum thickness at any point
AssemblyFrom inner to outer: Inner Conductor, Inner Insulation, optional Semi Conductive Insulation, Inner Shield, Middle Insulation, Outer Conductor, Outer Insulation, Outer Shield, optional Aramid braid, optional tape and overall Jacket.
ShieldMetal Shields and/ or Braids.
JacketExtruded TPU, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024