APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11763 Issued:2018-10-30
Revised:New
Style 11763 Single Conductor with Extruded Non-Integral Jacket

Rating80 deg C,150 Vac Cable flame, VW-1 flame.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
ShieldOptional
CoveringOptional for one layer jacket. None for two layers jacket.
JacketExtruded PVC. One layer or two layers jacket, thickness in accordance with the table below. Two layers jacket are extruded simultaneously and not separable in the same base compound, but should be differed with color. The thickness of individual layer is not specified. One layer jacket thickness (mils) or two layers total thickness (mils)
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0-2.500 inch15 mils12 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of Class 2 circuits

UL and the UL Logo are trademarks of UL LLC © 2024