APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11796 Issued:2019-02-14
Revised:New
Style 11796 Insulated Busbar

Rating105 deg C, 1500 Vac Horizontal flame, -20C optional.
Conductor20 AWG - 2000 kcmil, Flat. Thickness 0.5 - 1.0 mm, Width 15.5 - 65.0 mm.
InsulationExtruded PVC, 72 mils minimum average thickness, 68 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024