Rating | 80 deg C, 1000 Vac, Horizontal flame. |
|
Conductor | 36 AWG min., solid or stranded. |
|
Insulation | Labeled |
|
Covering | Optional |
|
Shield | Optional |
|
Jacket | Extruded TPE |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.00 inch | 45 mils | 36mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
| 1.501-2.500 inch | 80 mils | 64 mils |
| 2.500 inch and larger | 110 mils | 88 mils |
|
Braid | Optional |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|