Rating | 60 deg C, 600 Vac, Horizontal flame, 60 deg C Oil, Gasoline Resistant |
|
Conductor | 18 AWG - 16 AWG solid or stranded round |
|
Insulation | Extruded PVC, 30 mils minimum average, 27 mils minimum thickness at any point. |
|
Covering | Extruded Nylon, 5 mils minimum average thickness, 4 mils minimum thickness at any point |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | At temperatures not exceeding 60 deg C in air, or where exposed to mineral oil or gasoline vapors; or ordinary ambient temperatures where exposed to gasoline. Surface Marking: All wire of this type shall have "Gasoline-Resistant" or "Gasoline and Oil Resistant" printed in ink on the surface of the insulation at intervals not greater than six inches. |
|