APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11810 Issued:2019-05-30
Revised:New
Style 11810 Single Conductor with Extruded Insulation

Rating80 deg C, 30 Vac, no flame.
Conductor30 AWG - 500 kcmil, solid or stranded.
InsulationExtruded TPE
Conductor sizeAverage thicknessMinimum thickness at any point
30-20 AWG4 mils3 mils
18-16 AWG8 mils7 mils
14-10 AWG15 mils13 mils
9-8 AWG20 mils18 mils
7- 2 AWG30 mils27 mils
1-4/0 AWG40 mils36 mils
250-500 kcmil50 mils46 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing into Cables.

UL and the UL Logo are trademarks of UL LLC © 2024