APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11826 Issued:2019-09-26
Revised:2024-03-25
Style 11826 Single conductor employing a non-extruded covering.

Rating200 deg C, 300 Vac, Horizontal flame.
Conductor50 AWG - 19 AWG, nickel-chromium-alloy, stranded or resistance wire which is one through fifteen laid parallel resistance wire spirally wrapped around a fiberglass core with maximum 0.59 inch interval, core may be coated with silicone rubber. A separator consists of polyimide tape or PTFE tape which is not over 50% overlap may be used between resistance wire and insulation as intended to bind of conductor assembly.
InsulationExtruded PTFE, 18 mils minimum average thickness, 16 mils minimum thickness at any point.
CoveringFiberglass braid treated with silicone varnish coating, 5 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.