| Rating | 80 deg C,300 Vac Horizontal flame. |
|
| Conductor | 50 AWG - 4/0 AWG, solid or stranded. |
|
| Insulation | Extruded PE, 12 mils minimum average thickness, 10 mils minimum thickness at any point. |
|
| Conductive Coating | Optional. May be provided over the insulation and/or over the inner jacket. |
|
| Assembly | Single conductor employing PE insulation, optional conductive coating, optional inner shield, optional inner jacket, optional conductive coating, required outer shield and overall PVC jacket. |
|
| Inner Shield | Optional. |
|
| Inner Jacket | Optional, thickness not specified. |
|
| Conductive Coating | Optional, provided over the inner jacket. |
|
| Outer Shield | Metal braid, serve or metal tape with or without a drain wire, shall be provided under the overall jacket. |
|
| Outer Jacket | Extruded PVC, 12 mils minimum average thickness, 10 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal Wiring. |
|