APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11837 Issued:2019-10-29
Revised:2019-10-31
Style 11837 Single Conductor with Extruded Insulation and Non-Integral Jacket

Rating105 deg C,600 Vac Cable flame.
Conductor44 AWG - 10 AWG, solid or stranded, coated.
InsulationExtruded PVC core, 26 mils minimum average thickness, 22 mils minimum thickness at any point.
AssemblySingle conductor, with PVC insulation core with outer windings of R/C magnet wire (OBMW2), 2 or more layers, alternating direction of lay, covered by a shield, drain wire and non-integral jacket.
ShieldOptional
Drain WireOptional
JacketExtruded TPU
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
2.501-4.00011088
4.001 and larger140112
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024