APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1184 Issued:1959-05-01
Revised:2011-09-22
Style 1184 Single Conductor with Extruded Insulation and Extruded Jacket

RatingInsulation - 60 deg C, 600 Vac. PVC Jacket - 300 V ac. Horizontal flame.
Conductor26 AWG - 16 AWG, solid or stranded.
InsulationExtruded PE, 31 mils minimum average thickness, 28 mils minimum thickness at any point.
ShieldMetal serve, braid, or equivalent, conductive thermoplastic with drain wire, or aluminum-faced polyester with drain wire. Uninsulated drain wire optional where not specified.
JacketExtruded PVC, 16 mils minimum average thickness, 13 mils minimum thickness at any point. Or lacquered braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral. When used, "Conductive PVC Shield" required in contrasting color at intervals of two feet or less
UsePhonograph Pick-Up and Volume Control: or as internal wiring of appliances at temperatures. When used, "Conductive PVC Shield" required in contrasting color at intervals of two feet or less.