APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11855 Issued:2020-02-14
Revised:New
Style 11855 Single Conductor with Extruded Insulation

Rating80 deg C,600 Vac.
Conductor50 AWG - 500 kcmil, solid or stranded.
InsulationExtruded PP, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing into Jacketed Cables.