APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11861 Issued:2020-04-22
Revised:New
Style 11861 Single Conductor with Non-Extruded Insulation and Non-Integral Extruded Jacket.

Rating90 deg C, 1500 Vdc, Horizontal flame.
Conductor30 AWG, stranded.
InsulationPTFE tape, 11 mils total minimum average thickness, 10 mils total minimum thickness at any point.
Inner ShieldPTFE conductive polymeric tape having a volume resistivity not exceeding 50,000 ohm-centimeters, thickness not specified, and 38 AWG metal coated copper braid, minimum 90% coverage.
CoveringExtruded FEP, 16 mils minimum average thickness, 14 mils minimum thickness at any point.
Outer ShieldPTFE conductive polymeric tape having a volume resistivity not exceeding 50,000 ohm-centimeters, thickness not specified, and 38 AWG metal coated copper braid, minimum 90% coverage.
JacketExtruded TPU, 16 mils minimum average thickness, 14 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025