APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11862 Issued:2020-04-22
Revised:New
Style 11862 Heating Wire

Rating75 deg C,125 Vac, Horizontal flame.
Conductorstrands of hard drawn copper or copper alloy Resistance Wire) resistance wire, each 45 thru 20 AWG, wound on a rayon, cotton, figerglass or tetron yarn core. Wires may be flattened.
Covering(Plastic Thermo-Senser)Extruded PVC or Polyamid, 3 mils minimum thickness at any point
Outer Conductor (Senser Wire)45-30 AWG flattened hard drawn copper or nickel wire wound 10-55 turns per inch around above conductor assembly with covering.
Contamination BarrierOptional - A longitudinally applied wrap of 0.5 mil or Barrier heavier Polyester tape.
InsulationPVC, 14 mils minimum average thickness, 12 mils minimum thickness at any point.
standardAppliance Wiring Material UL 758.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn Electrically Heated Blankets or Heating Pads where exposed to temperatures not exceeding 75 deg C.

UL and the UL Logo are trademarks of UL LLC © 2025