Rating | 75 deg C,125 Vac, Horizontal flame. |
|
Conductor | strands of hard drawn copper or copper alloy Resistance Wire) resistance wire, each 45 thru 20 AWG, wound on a rayon, cotton, figerglass or tetron yarn core. Wires may be flattened. |
|
Covering(Plastic Thermo-Senser) | Extruded PVC or Polyamid, 3 mils minimum thickness at any point |
|
Outer Conductor (Senser Wire) | 45-30 AWG flattened hard drawn copper or nickel wire wound 10-55 turns per inch around above conductor assembly with covering. |
|
Contamination Barrier | Optional - A longitudinally applied wrap of 0.5 mil or Barrier heavier Polyester tape. |
|
Insulation | PVC, 14 mils minimum average thickness, 12 mils minimum thickness at any point. |
|
standard | Appliance Wiring Material UL 758. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | In Electrically Heated Blankets or Heating Pads where exposed to temperatures not exceeding 75 deg C. |
|