APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11865 Issued:2020-05-12
Revised:2021-11-02
Style 11865 High voltage DC wire with other-than-extruded insulation and non-integral jacket.

Rating90 deg C, 20000 Vdc, Horizontal flame.
Conductor18 AWG, stranded.
InsulationPTFE tape, 26 mils total minimum average thickness, 23 mils total minimum thickness at any point.
Inner ShieldPTFE conductive polymeric tape having a volume resistivity not exceeding 50,000 ohm-centimeters, thickness not specified, and 38 AWG metal coated copper braid, minimum 90% coverage.
CoveringExtruded FEP, 23 mils minimum average thickness, 21 mils minimum thickness at any point.
Outer ShieldPTFE conductive polymeric tape having a volume resistivity not exceeding 50,000 ohm-centimeters, thickness not specified, and 38 AWG metal coated copper braid, minimum 90% coverage.
JacketExtruded TPU, 23 mils minimum average thickness, 21 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025