APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11872 Issued:2020-07-10
Revised:New
Style 11872 Single conductor with extruded insulation and non-extruded covering.

Rating105 deg C, 90 Vac, Horizontal flame.
Conductor36 AWG - 16 AWG, solid or stranded.
InsulationExtruded PFA consists of two concentric tubes with integral bridges to maintain air gap between tubes, overall thickness - 7 mils minimum average thickness and 6 mils minimum at any point, inner tube thickness - 1 mil minimum at any point, outer tube thickness - 1 mil minimum at any point, and inter bridge thickness - 1 mil minimum at any point.
ShieldOptional.
CoveringPETP tape with polyester adhesive, combination thickness of tape and adhesive 0.3 mils minimum, 20 percent minimum overlap, spirally wrapped.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring where not subject to mechanical abuse or movement.

UL and the UL Logo are trademarks of UL LLC © 2024