Rating | 80 deg C, 300 Vac, Cable flame. |
|
Insulated Conductor | Labeled or complying with the AWM manufacturer's Procedure. |
|
Assembly | Single insulated conductor, inner metal shield, inner jacket, outer metal shield and outer jacket. |
|
Inner Shield | Metal tape or braid provided over the insulation. |
|
Inner Jacket | Extruded TPE with minimum average thickness 9 mils, minimum thickness at any point 8 mils. |
|
Outer Shield | Metal tape or braid provided under the overall jacket. |
|
Outer Jacket | Extruded TPU. |
| Diameter of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.000 inch | 45 mils | 36 mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
| 1.501-2.500 inch | 80 mils | 64 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|