APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11892 Issued:2020-09-08
Revised:New
Style 11892 Single conductor with extruded non-integral inner and outer jackets

Rating80 deg C, 300 Vac, Cable flame.
Insulated ConductorLabeled or complying with the AWM manufacturer's Procedure.
AssemblySingle insulated conductor, inner metal shield, inner jacket, outer metal shield and outer jacket.
Inner ShieldMetal tape or braid provided over the insulation.
Inner JacketExtruded TPE with minimum average thickness 9 mils, minimum thickness at any point 8 mils.
Outer ShieldMetal tape or braid provided under the overall jacket.
Outer JacketExtruded TPU.
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.