APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11893 Issued:2020-09-08
Revised:New
Style 11893 Single conductor with extruded non-integral inner and outer jackets

Rating80 deg C, 1000 Vac, Horizontal flame.
Insulated ConductorLabeled or complying with the AWM manufacturer's Procedure.
AssemblySingle insulated conductor, inner metal shield, inner jacket, outer metal shield and outer jacket.
Inner ShieldMetal tape or braid provided over the insulation.
Inner JacketExtruded TPE with minimum average thickness 9 mils, minimum thickness at any point 8 mils.
Outer ShieldMetal tape or braid provided under the overall jacket.
Outer JacketExtruded TPU with minimum average thickness 30 mils, minimum thickness at any point 24 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.