APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11908 Issued:2020-12-03
Revised:2020-12-07
Style 11908 Single conductor wire using non-integral jacket.

Rating90 deg C, 300 Vac, Cable flame, Sunlight Resistance.
Conductor44 AWG - 10 AWG, solid or stranded.
InsulationExtruded PTFE which consists of Maximum seven concentric tubes with integral bridges to maintain air gap between tubes, overall thickness - 12 mils min average and 11 mils min at any point, inner tube thickness - 6 mils min at any point, outer tube thickness - 6 mils min at any point, and inter bridge thickness - 8 mils min at any point.
ShieldRequired
JacketExtruded TPU, 15 mils min average, 12 mils minimum at any point. See facing page for compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024