APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1192 Issued:1959-06-29
Revised:2012-04-27
Style 1192 Single conductor with extruded insulation.

Rating105 deg C, 300 Vac, Horizontal flame.
ConductorMinimum 47 AWG resistance wire wound for a minimum 20 turns per inch on a Polyester yarn, or Fiberglass yarn core.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
CoveringExtruded nylon (polyimide), 2 mils minimum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerators where exposed to temperatures not exceeding 105 deg C and where not subjected to flexing or motion.