APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11921 Issued:2021-03-30
Revised:2021-03-29
Style 11921 Single Conductor using Non-Integral Extruded Jacket

Rating80 deg C,30 Vac Horizontal flame.
Conductor44 AWG - 10 AWG, solid or stranded.
InsulationExtruded PVC or Extruded PE, 6 mils minimum average thickness, 5 mils minimum thickness at any point.
AssemblyInsulated conductor with optional inner covering, optional inner shield, optional inner braid, jacket, optional outer shield and optioal outer covering.
Inner CoveringOptional.
Inner ShieldOptional.
JacketExtruded PVC, 9 mils minimum average thickness, 7 mils minimum thickness at any point.
Outer ShieldOptional.
Outer CoveringOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024