APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1193 Issued:1959-06-29
Revised:2012-10-17
Style 1193 Insulated Heating Wire.

Rating105 deg C, 300 V, Horizontal flame.
ConductorMinimum 0.0015 inch diameter resistance wire wound for a minimum 20 turns per inch on a Polyester, Rayon or Fiberglass yarn core.
InsulationExtruded PVC, 30 mils minimun average, 27 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerators where not subjected to flexing or motion.