APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11940 Issued:2021-06-21
Revised:2021-06-28
Style 11940 Single conductor with extruded insulation

Rating105 deg C,300 Vac Horizontal flame.
Conductor(strands of copper or copper alloy or other suitable resistance wire) resistance wire, 45 to 14 AWG, wound on a polyester, rayon, cotton, figerglass or fiber yarn core. Wires may be flattened, or may be enameled wire.
InsulationExtruded PVC, 6 mils minimum average thickness,5 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025