APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1200 Issued:1959-08-14
Revised:2011-08-01
Style 1200 Single conductor with extruded insulation

Rating80 deg C, 300 Vac, Horizontal flame.
ConductorMinimum 1.75 mils diameter resistance wire wound for a minimum of 25 turns per inch on a Rayon, Cotton, Polyester, Fiberglass or Nylon yarn core.
InsulationPVC, 60 mils min average, 54 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor refrigerator heating at temperatures not exceeding 80 deg C and in dry location where not subjected to repeated flexing in use.